Minimum Order Quantity | 1 Piece |
Application Media | Water |
Material | Stainless Steel |
Brand | Rose Mount,ABB Honeywell |
Usage/Application | Water |
Display | Digital |
Power Supply | 230v |
Operation Pressure | 50BAR |
Minimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Brand | Honeywell |
Application Media | Any Liquid |
Usage/Application | Industrial |
Model Name/Number | Orifice flow meter |
Display | Digital |
Flow Range | 0-500tons per hour |
Line Sizes | 1" - 50" |
Turndown | 10:1 |
Minimum Order Quantity | 1 Piece |
Usage/Application | Industrial |
Type Of Instruments | FLOWMETER |
Material | Stainless Steel |
Color | Gray |
Brand | I-TEK |
Model Name/Number | ROSEMOUNT HONEYWELL ABB |
Accuracy | 1% |
Pressure method | The upstream end uses the radial pressure to take the pressure, and the downstream part uses the throat to take the pressure. |
Nominal pressure | ≤6.3MPa |
Nominal diameter | 50-2200mm |
Accuracy | ±0.7%-1.5% |
Scope of application | Opening diameter ratioβ:0.4≤β≤0.7 |
Reynolds number range:2*10???≥ReD≥2*10??? | |
Outflow coefficient c:c=0.985 |
Venturi’s are very useful when considering erosion and pressure recovery restraints.
Our Venturi meters can cope with a wide range of mediums:
from Gas, water, Chemical, Crude, Slurry to even high temperature Steam,
and can be used for many apllications,
such as irigation systems, metallurgy,
power stations, chemical industry,
water suply project, etc.
*Your information is safe with us.
Minimum Order Quantity | 1 Piece |
Model Name/Number | Averaging Pitot tubes Annubar SAP bars |
Material | SS316 |
Brand | i-Tek |
Size | 500mm |
Accuracy | 1% |
Beta Ratio | 0.65 |
Flow Calculation | ISO5167 |
Brand | Honeywell |
Application Media | Any Liquid |
Material | Stainless Steel |
Electronics Enclosure | IP65 |
Flow Range | As Per Requirement |
Accuracy | 0.1% |
Country of Origin | Made in India |
Display | Digital |
Brand | HONEYWELL |
Temperature | As per Requirement |
Packaging Type | BOX |
Model Name/Number | VersaFlow Vortex |
Accuracy | 1 |
Country of Origin | Made in India |
*Your information is safe with us.
Usage/Application | Automotive |
Material | Stainless Steel |
Application Media | Any Liquid |
Brand | Groz |
Line Size | 15NB |
Display | Local |
Operating Temperature | 30DEGC |
Flow Range | 500LPH |
Operating Pressure | 5BAR |
Flowmeters are precisely what you need when it comes to accurate consumption or dispensing of diesel. It is built on the time-tested positive displacement principle using oscillating piston design. This equipment made by the best diesel flow meter manufacturers in India combines accurate and repeatable flow sensing and safety by the usage of certified electronics flameproof and weatherproof enclosure.
This flowmeter has records data readings in non-volatile memory that validate the aggregate flow on a display. Customers can also opt for a remote display option in diesel flow meter products. The internal moving part is protected with seals which ensure that liquid in the flow tube is measured before reaching the outlet.
Digital fuel flow meters can be attached to clean and non-corrosive liquids such as diesel, including marine diesel and high-speed diesel HSD. Commonly best-connected for processes where high precision is needed at a reasonable cost.
The Benefits of using Flowmeter for stock measurement in Diesel TanksMinimum Order Quantity | 1 Piece |
Material | Stainless Steel |
Usage/Application | Industrial |
Brand | UFI |
Rated Pressure | 1000BAR |
Size | 5-10 inch |
Accuracy | 0.1% |
Beta Ratio | 0.6-0.7 |
An Orifice Meter is basically a type of flow meter used to measure the rate of flow of Liquid or Gas, especially Steam, using the Differential Pressure Measurement principle. It is mainly used for robust applications as it is known for its durability and is very economical.
As the name implies, it consists of an Orifice Plate which is the basic element of the instrument. When this Orifice Plate is placed in a line, a differential pressure is developed across the Orifice Plate. This pressure drop is linear and is in direct proportion to the flow-rate of the liquid or gas.
Since there is a drop in pressure, just like Turbine Flow meter, hence it is used where a drop in pressure or head loss is permissible.
An orifice meter is a conduit and a restriction to create a pressure drop. A nozzle, venturi or thin sharp edged orifice can be used as the flow restriction.
In order to use any of these devices for measurement it is necessary to empirically calibrate them. That is, pass a known volume through the meter and note the reading in order to provide a standard for measuring other quantities.
Due to the ease of duplicating and the simple construction, the thin sharp edged orifice has been adopted as a standard and extensive calibration work has been done so that it is widely accepted as a standard means of measuring fluids. Provided the standard mechanics of construction are followed no further calibration is required.
A linearly extending section of the same diameter as the inlet pipe for an end connection for an incoming flow connection. Here we measure the inlet pressure of the fluid / steam / gas.
Orifice PlateAn Orifice Plate is inserted in between the Inlet and Outlet Sections to create a pressure drop and thus measure the flow.
Outlet SectionA linearly extending section similar to the Inlet section. Here also the diameter is the same as that of the outlet pipe for an end connection for an outgoing flow. Here we measure the Pressure of the media at this discharge.
As shown in the adjacent diagram, a gasket is used to seal the space between the Orifice Plate and the Flange surface, prevent leakage.
Sections 1 & 2 of the Orifice meter, are provided with an opening for attaching a differential pressure sensor (u-tube manometer,differential pressure indicator).
Minimum Order Quantity | 1 Piece |
Brand | Emerson |
Application Media | Any Liquid |
Usage/Application | Automotive |
Material | Stainless Steel |
Model Name/Number | Integral Flow transmitter |
Display | Digital |
Flow Range | 0-500tons per hour |
Line Sizes | 1" - 50" |
Turndown | 10:1 |
*Your information is safe with us.
Type | Liquid Flow Sensor |
Application | Industrial |
Flow Rate | 0.5 to 25 liter / minute |
Operational Mode | Bidirectional |
Supply Voltage | 5 V DC |
Material | Plastic |
Display | Digital |
Model Name/Number | VersaFlow Vortex |
Power Supply | 24VDC |
Accuracy | 1 |
Electronics Enclosure | IP65 |
Brand | Honeywell |
Model Name/Number | Versa Flow Coriolis Mass Flow meter |
Color | White |
Display | Digital |
Power Supply | 24VDC |
Accuracy | 0.1% |
Electronics Enclosure | IP65 |
Brand | Honeywell |