Minimum Order Quantity | 1 Piece |
No. of Input Channel | 8 |
Brand | Allenbradley |
Model Name/Number | ALLENBRADLEY A-B 1756-OF8 ANALOG OUTPUT CARD |
Power | 24VDC |
Packaging Type | Box |
Country of Origin | Made in India |
Brand | Trinity Touch |
Usage/Application | Control Panel |
Number Of Poles | 2 Pole |
Coil Voltage | 24VDC |
Model Name/Number | TT-IMRB-08024D1S-C-RL |
No. of Contact | 1 PDT |
Relay | Omron,IDEC,Tyco,Honeywell or equivalent |
Type of connection | Screw connection (PCB terminals block) |
Model Name/Number | MVI56-MCM |
Brand | Prosoft |
Material | Plastic |
Compatible Brand | Netgear |
Country of Origin | Made in India |
Frequency | 50 Hz |
The MVI56E Communication Module allows for Modbus Master and/or Slave connectivity from Rockwell Automation ControlLogix processors to Modbus RTU/ASCII devices. Each MVI56E port can be configured as a Master or Slave.
The MVI56E-MCM and MVI56E-MCMXT act as input/output modules on the ControlLogix backplane, making Modbus data appear as I/O data to the processor. Two independently configurable serial ports can operate on the same or different Modbus networks. The MVI56E-MCM is designed for standard process applications and the MVI56E-MCMXT is designed for the Logix-XT control platform, allowing it to operate in extreme environments. It can tolerate higher operating temperatures, and has conformal coating to protect it from harsh or caustic conditions.
Modbus General SpecificationsCommunication parameters | Baud Rate: 110 baud to 115.2 kbps |
Modbus Modes | RTU mode (binary) with CRC-16 |
Floating Point Data | Floating point data movement supported, including configurable support for Enron and Daniel implementations |
Modbus Function Codes | 1: Read Coils Status |
Command List | Up to 325 commands per Master port, each fully configurable for function code, slave address, register to/from addressing and word/bit count. |
Optimized Polling | Configuration options allow Master ports and commands to be optimized to poll slaves with communication problems less frequently. |
Command Status/Error Monitoring | Command Status or Error codes are generated for each command as it executes, allowing careful monitoring o fcommunication health between the Master and its Slaves. |
Slave Polling Control | Master Port maintains a Slave Status list of all network Slaves. Polling of each Slave may be disabled and enabled using this list. |
Full Memory Access | A port configured as a Modbus Slave permits a remote Master to read from or write to any of the 5000 registers that make up the user memory database. |