Minimum Order Quantity | 1 Pack |
Type | Digital |
Model Name/Number | STF800 |
Brand | Honeywell |
Material | Stainless Steel |
Ambient Temperature | 10 to 50 deg C [14 to 122 deg F] |
Measuring Range | Up to 1001 |
Voltage V | 10.8 to 42.4 Vdc |
Country of Origin | Made in India |
Specifications for all STF800 models:
2-wire connection, 4-20mA + HART/DE/Foundation Fieldbus
Aluminium housing with polyester coating or 316 SS
Advanced Graphic Display
Standard accuracy 0.05%, optional up to 0.025%
Stability 0.01% per year, turndown ratio 100:1
Recommended calibration period: every 4 years
Certifications: SIL2/3/ATEX/IECEX/FM/CSA/Inmetro/CU-TR/Marine (DNV/ABS/BV/KR/LR)
STF724/ STF725??? -400 to 400 inH2O -1000 to 1000 mbar
STF732/ STF735??? -100 to 100 psi -7.0 to 7.0 bar
STF72F/ STF72P??? -400 to 400 inH2O -1000 to 1000 mbar
STF73F/ STF73P??? -100 to 100 psi -7.0 to 7.0 bar
Specifications for all STF700 models:
2-wire connection, 4-20mA + HART/DE/Foundation Fieldbus
Aluminium housing with polyester coating or 316 SS
Display with 2 lines
Standard accuracy 0.05%
Stability 0.02% per year, turndown ratio 100:1
Specifications for all STF700 Basic models:
2-wire connection, 4-20mA + HART 7
Aluminium housing with polyester coating or 316 SS
Display with 2 lines
Standard accuracy 0.065%
Stability 0.025% per year, turndown ratio 100:1
Recommended calibration period: every 2 years
Certifications: SIL2/3/ATEX/IECEX/FM/CSA/Inmetro/CU-TR
Type | Digital |
Model Name/Number | STF800 |
Brand | HONEYWELL |
Material | Stainless Steel |
Ambient Temperature | 10 to 50 deg C [14 to 122 deg F] |
Measuring Range | Up to 1001 |
Country of Origin | Made in India |
Standard accuracy 0.05%, optional up to 0.025%
Stability 0.01% per year, turndown ratio 100:1
Recommended calibration period: every 4 years
Certifications: SIL2/3/ATEX/IECEX/FM/CSA/Inmetro/CU-TR/Marine (DNV/ABS/BV/KR/LR)
STF724/ STF725??? -400 to 400 inH2O -1000 to 1000 mbar
STF732/ STF735??? -100 to 100 psi -7.0 to 7.0 bar
STF72F/ STF72P??? -400 to 400 inH2O -1000 to 1000 mbar
STF73F/ STF73P??? -100 to 100 psi -7.0 to 7.0 bar
Specifications for all STF700 models:
2-wire connection, 4-20mA + HART/DE/Foundation Fieldbus
Aluminium housing with polyester coating or 316 SS
Display with 2 lines
Standard accuracy 0.05%
Stability 0.02% per year, turndown ratio 100:1
Type | Digital |
Model Name/Number | STF800 |
Brand | HONEYWELL |
Material | Stainless Steel |
Frequency | 50Hz |
Ambient Temperature | 10 to 50 deg C [14 to 122 deg F] |
Specifications for all STF800 models:
2-wire connection, 4-20mA + HART/DE/Foundation Fieldbus
Aluminium housing with polyester coating or 316 SS
Advanced Graphic Display
Standard accuracy 0.05%, optional up to 0.025%
Stability 0.01% per year, turndown ratio 100:1
Recommended calibration period: every 4 years
Certifications: SIL2/3/ATEX/IECEX/FM/CSA/Inmetro/CU-TR/Marine (DNV/ABS/BV/KR/LR)
STF724/ STF725 -400 to 400 inH2O -1000 to 1000 mbar
STF732/ STF735 -100 to 100 psi -7.0 to 7.0 bar
STF72F/ STF72P -400 to 400 inH2O -1000 to 1000 mbar
STF73F/ STF73P -100 to 100 psi -7.0 to 7.0 bar
Specifications for all STF700 models:
2-wire connection, 4-20mA + HART/DE/Foundation Fieldbus
Aluminium housing with polyester coating or 316 SS
Display with 2 lines
Standard accuracy 0.05%
Stability 0.02% per year, turndown ratio 100:1
Specifications for all STF700 Basic models:
2-wire connection, 4-20mA + HART 7
Aluminium housing with polyester coating or 316 SS
Display with 2 lines
Standard accuracy 0.065%
Stability 0.025% per year, turndown ratio 100:1
Recommended calibration period: every 2 years
Certifications: SIL2/3/ATEX/IECEX/FM/CSA/Inmetro/CU-TR
*Your information is safe with us.
Type | Digital |
Model Name/Number | STF800 |
Brand | Honeywell |
Usage/Application | Industrial |
Material | Stainless Steel |
Ambient Temperature | 50 Degree Celsius |
Measuring Range | Up to 1001 |
Low power | 1-5 VDC |
Additional Transmitter options | Remote Display And Interface |
Process Temperature | -4 to +194 DegreeF |
Process Pressure | Up to 10000 psi 689 Bar |